______________________________________________________________________________________
Whilst SGX has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use thereof and also reserves the right to
change the specification of goods without notice. SGX accepts no liability beyond the set out in its standard conditions of s
ale in respect of infringement of third party patents arising from
the use of SGX products in accordance with inf
ormation contained herein.
In case of modification of the product, SGX d
isclaims all liability.
SGX Europe sp .z o.o. Poland REGON: 362332227 DS-0141, Issue 3, 29-Jul-2016, Page 1
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
SGX-4DT
Industrial Dual Toxic Sensor (CO and H
2
S)
(Application : Portable Multi-Gas Detectors)
PERFORMANCE
Range
0 – 500 ppm CO
0 – 200 ppm H
2
S
Output Signal
80 ± 30 nA/ppm CO
775 ± 275 nA/ppm H
2
S
Typical Baseline Range
±2 ppm CO equivalent
±0.5 ppm H
2
S equivalent
Filter Capacity
> 20000 ppm hours CO
Linearity
Linear
Response time (T
90
)
<30 s
Maximum Overload
Long-Term Output Drift
<10% per annum
Recommended Load
Resistor
10 ohms (CO)
10 ohms (H
2
S)
Repeatability
<±3% CO equivalent
<±2% H
2
S equivalent
Resolution
±1 ppm CO typical
±0.5 ppm H
2
S typical
Warranty
2 years
Bias
No Bias
OPERATING CONDITIONS
Temperature Range
-30°C to +50°C
Operating Humidity
15 – 90% RH
(non-Condensing)
Pressure range
800 to 1200 mbar
Operating Circuit
See Application Note 2
Recommended Storage
Temperature
0°C to 20°C
Storage Life
6 months in original
Packaging (0 to 20°C)
Expected Operating Life
> 24 months in air
INTRINSIC SAFETY DATA
Maximum at 2000 ppm
0.3 mA
Maximum o/c Voltage
1.3 V
Maximum s/c Current
<1.0 A
PRODUCT DIMENSIONS
All dimensions in mm
All tolerances ±0.15 mm
IMPORTANT NOTES
• All performance is based on conditions at 20°C,
50% RH and 1 atm, using SGX recommended
circuitry.
• Sensor performance is temperature dependant;
please contact SGX for temperature performance
other than 20°C.
• Do not solder to the connector pins as this may
damage the sensor and thereby invalidate the
warranty.
• Details on recommended connector pins can be
found in the Frequently Asked Questions within
the Gas Sensor section of the SGX website.
• This device is designed to be RoHS compliant.