www.switches-sensors.zf.com
Page 1 of 2, Last update 2017-08-08, Specifications subject to change without notice.
Magnetic Proximity Sensors (Hall Effect)
MP1021 Sensors
Digital Hall-effect position sensor in low-profile flange-mount housing
Description
The MP1 Series sensors are one-piece non-contact solid-state position sensors. The sensors operate through the use of Hall Effect
technology with magnetic fields generated by permanent magnets. They provide a sinking current output.
Features Typical Applications
â€ĸ Solid state reliability
â€ĸ Flange-mount housing
â€ĸ Stable output over operating temperature range
â€ĸ Compatible with unregulated power supply
â€ĸ Open collector (NPN) output can be used with bipolar or CMOS
logic circuits with suitable pull-up resistor
â€ĸ North pole sensitive
â€ĸ Unipolar device (MP102103), (obsolete – MP102102, MP102103)
â€ĸ Latching versions (obsolete – MP102104, MP102105, MP102106)
â€ĸ RoHS compliant
â€ĸ IP67
â€ĸ Door position & interlock
â€ĸ Limit switch
â€ĸ Flow/speed
â€ĸ Home security
â€ĸ Pedal switch
Environmental Specifications
O
p
eratin
g
Tem
p
erature -40 °C to 85
Íŧ
C
(
-40
Íŧ
F to 185
Íŧ
F
)
Stora
g
e Tem
p
erature -40 °C to 85
Íŧ
C
(
-40
Íŧ
F to 185
Íŧ
F
)
In
g
ress Protection IP67
Electrical Specifications
O
p
eratin
g
Su
pp
l
y
Volta
g
e 4.5 to 24 VDC
Su
l
Current 2.5 mA t
yp
., 5 mA max.
Out
p
ut Current
(
Sink
)
25 mA max.
Maximum Reverse Volta
g
e 30 VDC
Recommended Pull-U
p
Resistor See chart
Mechanical Specifications
Housin
Material
Glass-reinforced plastic
Turn on / off (MP102101, MP102102, MP102103)
300 Gauss / 95 Gauss
Turn on / off (MP102104, MP102105, MP102106)* 60 Gauss / 60 Gauss
*MP102104, MP102105, MP102106 are latching sensors and release when 60 Gauss is applied to the south pole
*
MP102101 Not commonly stocked
#
Obsolete as of June, 2016
Products
Part Number Sensin
g
Location Termination
MP102103 C 24 AWG x 314 mm
MP102101* A 24 AWG x 314 mm
MP102102
#
B 24 AWG x 314 mm
MP102104
#
A 24 AWG x 314 mm
MP102105
#
B 24 AWG x 314 mm
MP102106
#
C 24 AWG x 314 mm
æ„ŸįŽ—å•†åŸŽ
www.switches-sensors.zf.com
Page 2 of 2, Last update 2017-08-08, Specifications subject to change without notice.
Note: An external pull-up resistor is required, the value of which is dependent on the supply voltage. The resistor should be connected
between the output and Vcc. Refer to the wiring diagram for lead colors or pin numbering as applicable.
Recommended External Pull-Up Resistor
Volts DC 5 9 12 15 24
Ohms 1
k
1.8
k
2.4
k
3
k
3
k
Open Collector Sinking Block Diagram
Dimensions mm (inches)
æ„ŸįŽ—å•†åŸŽ