PS1-CO-1000
PS4-CO-1000
Technical Specications
25 ± 10 nA / ppm
Sensitivity
Measurement Range
0 – 1000 ppm
Zero Current ± 100 nA
Maximum Overload 2000 ppm
Response Time
T50 < 10s,
T90 < 30s
Repeatability < 1%
Lower Detectable Limit (LDL) ≤ 2 ppm
Linear Range 1000 ppm
Resolution (16Bit ADC) 0.1ppm
Performance
Operating Humidity Range 15-95% RH
Pressure Range 800 to 1200 hPA
Storage Temperature
0 to 20℃
Temperature Range
-40°C to +55°C
Environmental Details
Operating Principle
Amperometric,
3-electrode
Recommended Load Resistor 100 Ω
Bias Voltage 0 mV
Warm Up Time
< 60 s
Operation
Long-Term Drift
< 1 %/month
Zero Drift in Clean Air
< 2 ppm
Storage Life
12 months
Expected Lifetime
> 5 years in air
Storage conditions
0-20°C
Warranty
12 months
Lifetime Details
Housing Material PPO
Housing
Important Notes
• All performance is based on conditions at 20°C,
50% RH and 1 atm, ow rate>150qcm/min,
using SGX recommended circuitry.
• Sensor performance is temperature dependant;
please contact SGX for temperature
performance other than 20°C.
• Do not solder to the connector pins as this may
damage the sensor and thereby invalidate the
warranty.
• Details on recommended connector pins can be
found in the Frequently Asked Questions within
the Gas Sensor section of the SGX website.
Features
•
Small size
•
Wide teperature range
•
Low cross sensitivity
•
No electrolyte leakage
•
High sensitivity
•
Fast response time
•
Extreme linear response up to high
concentration
SGX Europe Sp. z o.o.
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
T: +48 (0) 32 438 4778
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
© SGX Sensortech 2012-2022 DS-0368-PS1&PS4-CO-1000, Issue 1, 23-Jan-2022, Page 1/3
PS1-CO-1000 < 0.7g
PS4-CO-1000 < 6g
Weight
Key applications
• TLV Monitoring
• Oil & Petrochemical Industry
• Leak detection
• Steel Industry
• Parking Garages