Quality, Safety, Responsibility
Datasheet
Fluorine sensor
SGX Liquid Electrochemical Gas Sensors
These SGX Sensors use a revolutionary innovation in electrochemical sensing, which detects the output
signals from the electrochemical reactions of dierent gases. Furthermore, it accurately measures gas
concentration through the magnitude of the signal. These specialised sensors consist of three catalytic
electrodes, liquid electrolyte and gas diusion holes. Through the diusion holes, the gas reaches the
sensor's working electrode, where an electrochemical reaction takes place at the so-called 3-phase
boundary. A current signal is generated at the output, which is linearly proportional to the gas concentration.
SGX-F2-5
SGX-F2-5
Technical Specications
-260 ± 80 nA/ppm
Sensitivity
Measurement Range
0 5 ppm
Zero Current ± 20 nA
Maximum Overload 10 ppm
Response Time
T50 < 20s,
T90 < 60s
Repeatability 2%
Lower Detectable Limit (LDL) 0.05 ppm
Linear Range 5 ppm
Resolution (16Bit ADC) < 0.01ppm
Performance
Operating Humidity Range 15-95% RH
Pressure Range 800 to 1200 hPA
Storage Temperature
0 to 20
Temperature Range
-20°C to +40°C
Environmental Details
Operating Principle
Amperometric
Recommended Load Resistor 220
Bias Voltage 0 mV
Warm Up Time
< 60 s
Operation
Long-Term Drift
< 1 %/month
Zero Drift in Clean Air
< 1 ppm
Storage Life
6 months
Expected Lifetime
24 months
Storage conditions
0-20°C
Warranty
12 months
Lifetime Details
Housing Material PPO
Housing
Important Notes
All performance is based on conditions at 20°C,
50% RH and 1 atm, ow rate>150qcm/min,
using SGX recommended circuitry.
Sensor performance is temperature dependant;
please contact SGX for temperature
performance other than 20°C.
Do not solder to the connector pins as this may
damage the sensor and thereby invalidate the
warranty.
Details on recommended connector pins can be
found in the Frequently Asked Questions within
the Gas Sensor section of the SGX website.
Features
Small size
Water based electrolyte
High selectivity
High sensitivity
Excellent sensitivity at low temperatures
Double sealed housing for advanced
leakage protection
SGX Europe Sp. z o.o.
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
T: +48 (0) 32 438 4778
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
© SGX Sensortech 2012-2022 DS-0405-SGX-F2-5, Issue 1, 10-Feb-2022, Page 1/3
< 8g
Weight
Key applications
General Industry
Environmental Monitoring
Leak detection
Emissions
TLV-monitoring
Semiconductor Industry
Portable and Fixed Point Applications
Water Treatment, Plants, Swimming,
Pools, Chemical Industry
SGX Europe Sp. z o.o.
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
T: +48 (0) 32 438 4778
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
© SGX Sensortech 2012-2022 DS-0405-SGX-F2-5, Issue 1, 10-Feb-2022, Page 2/3
Dimensions
Cross Sensitivity
Gas
Formula
Test Concentration
Sensor Reading
Ammonia NH
3
CO
B
2
H
6
H
2
HCL
HF
H
2
S
O
3
100ppm 0ppm
Carbon Monoxide 100ppm 0ppm
Diborane
Hydrogen
0.6ppm
1000ppm
0.3ppm
0ppm
Hydrogen Chloride
Hydrogen Fluoride
20ppm
3ppm
0ppm
0ppm
Hydrogen Sulphide 10ppm 0ppm
Ozone 0.25ppm 0.05ppm
Note:
1) The above interference factors may vary due to different sensors and service life, please refer to the actual test results.
2) This table is not complete for all cross gases, other gas please contact with us.