SSI SERIES – AMPLIFIED STAINLESS STEEL PRESSURE SENSORS
TE CONNECTIVITY SENSORS /// SSI SERIES E / 11671 / D - 11/2021
Performance characteristics
(V
S
= 5.0 V
DC
, T
A
= 25°C, analog output signal is ratiometric to V
S
, digital output signal is not ratiometric to V
S
)
Total accuracy (-20 to 85 °C)
3
ANALOG PERFORMANCE CHARACTERISTIC
Output at min. specified pressure
DIGITAL PERFORMANCE CHARACTERISTIC
Output at min. specified pressure
Specification notes (cont.)
(3) Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature
effects. Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any
point within the operating pressure range for increasing and decreasing pressure. Calibration errors include the
deviation of offset and full scale from nominal values.
(4) Max. delay time between pressure change at the pressure die and signal change at the output.
(5) The response time depends on the adjusted internal A/D resolution of the sensor. For 13 bit it is typ. 2 ms. Other A/D
resolutions and response time are available on request. Please contact TE Connectivity for further information.
(6) Sensors with lower current consumption are available on request. Please contact TE Connectivity for further information.
(7) Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure.