NTCAIMME3
www.vishay.com
Vishay BCcomponents
Revision: 03-Mar-17
1
Document Number: 29131
For technical questions, contact: nlr@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
NTC Thermistors, Miniature Immersion Sensor
Note
• Other R
25
values and tolerances available upon request
Fig. 1 - Mounting example with sealing ring and screw
FEATURES
• Fast time response for fluid immersion
applications
• Reduced thermal gradient, due to the use of
small tip dimensions and thin insulated wire
• Sensor for permanent contact with water or
other liquids
• Material categorization: for definitions of
compliance please see www.vishay.com/doc?99912
APPLICATIONS
Immersion sensor used for temperature measurement,
sensing and control in:
• Water boilers
• Heating systems
• Chiller systems
• Water and used water systems
• Water and oil tanks
• Consumer appliances, Coffee machines
• Industrial appliances
• Solar heating systems
DESCRIPTION
Miniature insulated chip NTC thermistor mounted in a
SS304 housing with or without brass collar for sealed
mounting and twin PVC insulated AWG#30 lead wire
connection.
MOUNTING
• The sensor can be mounted by means of a sealing O-ring
and screw
• The end wire can be soldered, or crimped to a connector
• Optional connector for Wire-to-Wire or Wire-to-Board
connections
• The contact area with the liquid is preferably min 10 mm
down from the tip and max to the brass collar location (see
Fig. 1 for mounting example)
• Not intended for corrosive or high acidic liquids
• The epoxy lead-wire side can not be in permanent contact
with liquids, or water
PACKAGING
Available in plastic bags of 250 pieces.
DESIGN-IN SUPPORT
• Other resistance curves and tolerances are available on
request
• Consult Vishay for other lead length
• 3D solid models: www.vishay.com/doc?29106
• For complete RT curve computation, visit:
www.vishay.com/thermistors/ntc-curve-list/
QUICK REFERENCE DATA
PARAMETER VALUE UNIT
Resistance value at 25 °C 10K
Tolerance on R
25
-value ± 3 %
B
25/85
-value 3984 K
Tolerance on B
25/85
-value ± 0.5 %
Operating temperature range
at zero dissipation
-25 to +105 °C
Response time t 63.2 % of T
(air 25°C to water 85°C)
1.5 s
Dissipation factor
mW/KMounted in still air 2.8
In still water 5.6
Maximum power dissipation at 55 °C 100 mW
Min. dielectric withstanding voltage
between terminals and capsule (10 s)
500 V
AC
Insulation resistance at 500 V
DC
> 100M
Thermal gradient < 0.02 K/K
Weight 2.1 g
ELECTRICAL DATA AND ORDERING INFORMATION
R
25
R
25
-TOL. B
25/85
B
25/85
-TOL.
DESCRIPTION
SAP MATERIAL AND
ORDERING NUMBER
()(%) (K) (± %)
10 000 ± 3 3984 0.5 NTC Immersion 10K 3 % 3984K 0.5 % NTCAIMME3C90373
10 000 ± 3 3984 0.5 NTC 10K 3 % 3984K 0.5 % no ring NTCAIMME3C90686