______________________________________________________________________________________
Whilst SGX has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use thereof and also reserves the right to
change the specification of goods without notice. SGX accepts no liability beyond the set out in its standard conditions of sale in respect of infringement of third party patents arising from
the use of SGX products in accordance with information contained herein.
In case of modification of the product, SGX disclaims all liability.
SGX Europe sp .z o.o. Poland REGON: 362332227 DS-0144, Issue 4, 29-Jul-2016, Page 1
SGX Europe Sp. z o.o.
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
T: +48 (0) 32 438 4778
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
SGX-7CO
Industrial Carbon Monoxide Sensor
(Application : Fixed Gas Detectors)
PERFORMANCE
Range
0 1000 ppm
Output Signal
100 ± 20 nA/ppm
Typical Baseline Range
(pure air)
<±2 ppm CO equivalent
Linearity
Linear
Response time (T
90
)
<30 s
Maximum Overload
2000 ppm
Long-Term Output Drift
<5% per annum
Recommended Load
Resistor
10 ohms
Repeatability
<±1% CO equivalent
Resolution
< 0.5 ppm
Warranty
2 years
Bias
No Bias
OPERATING CONDITIONS
Temperature Range
-30°C to +50°C
Operating Humidity
15 90% RH
(non-Condensing)
Pressure range
800 to 1200 mbar
Operating Circuit
See Application Note 2
Recommended Storage
Temperature
0°C to 20°C
Expected Operating Life
> 24 Months in Air
INTRINSIC SAFETY DATA
Maximum at 2000 ppm
0.3 mA
Maximum o/c Voltage
1.3 V
Maximum s/c Current
<1.0 A
PRODUCT DIMENSIONS
All dimensions in mm
All tolerances ±0.15 mm
IMPORTANT NOTES
All performance is based on conditions at 20°C,
50% RH and 1 atm, using SGX recommended
circuitry.
Sensor performance is temperature dependant;
please contact SGX for temperature performance
other than 20°C.
Do not solder to the connector pins as this may
damage the sensor and thereby invalidate the
warranty.
Details on recommended connector pins can be
found in the Frequently Asked Questions within
the Gas Sensor section of the SGX website.
This device is designed to be RoHS compliant.
_______________________________________________________________________________________
© SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0144, Issue 4, 29-July-2016, Page 2
SGX Europe Sp. z o.o.
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
T: +48 (0) 32 438 4778
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
CROSS-SENSITIVITY DATA
GAS
SGX-7CO
Hydrogen Sulfide
<0.1 ppm
Sulfur Dioxide
0 ppm
Nitrogen Dioxide
-0.5 ppm
Nitric Oxide
<7 ppm
Hydrogen
<60 ppm
Chlorine
0 ppm
Ethylene
<90 ppm
Note: This table is for reference only and are typical values. Cross Sensitivities may not be linear and should not be scaled. Calibration should be carried out
with the actual gas at a known concentration.
TEMPERATURE
POISONING
SGX sensors are designed to operate in a wide range of harsh environments and conditions. However it is important
that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instrument and
operation. When using sensors on printed circuit boards (PCBs), degreasing agents should be used prior to the sensor
being fitted.